Home/Products/PAC 29% drinking water
GB 15892 · Al₂O₃ ≥ 29% · Potable water

Polyaluminium chloride 29%,
for water people actually drink.

[ Al2(OH)nCl6−n ]m  ·  Al₂O₃ ≥ 29%  ·  Insolubles ≤ 0.1%

The drinking-water grade: fewer insolubles, tighter heavy-metal limits, and production under a hygiene licence for potable-water contact. Specified for surface water, low-turbidity and algal water, colour and NOM removal, and membrane pretreatment.

29%Al₂O₃ MINIMUM
≤0.1%INSOLUBLES
6.5–8TARGET pH
LicencePOTABLE CONTACT
Al
Al
Al
Al
Al
Al
Al
Al
O
O
O
O
Pre-hydrolysed species — [Al₁₃O₄(OH)₂₄(H₂O)₁₂]⁷⁺ · potable-water grade
01 — Forms we supply

One grade,
two handling options.

Drinking-water duty does not allow a second-best form. Both options below are produced to GB 15892 with the same heavy-metal limits; they differ only in how the plant receives and dissolves them.

PAC-29 SD
29%
Al₂O₃ (spray-dried)
Insolubles≤ 0.1%
Basicity40–70%
Dissolution20–30 min
The standard potable grade for surface water plants. Low insolubles keep filter runs long and residual aluminium predictable.
PAC-29 LG
29%
Al₂O₃ (low-turbidity)
Insolubles≤ 0.05%
Basicity50–70%
Best forAlgal / low NTU
Tighter insolubles for low-turbidity, algal and reservoir water where every particle counts toward filtered-water turbidity.
PAC-29 L
10%
Al₂O₃ (liquid)
Basicity50–70%
Density1.19–1.22 kg/L
Dose factor× 3 solid
Liquid for plants with lined storage and no make-down room. Supplied in food-grade-lined IBC or drum.

All three are produced to GB 15892 and covered by the same hygiene licence for potable-water contact. The licence covers the manufacturing site, not a specific batch — ask for a copy with the quotation and check that the product name on it matches what you are buying.

02 — Technical data

What the COA will say.

Drinking-water limits are tighter than industrial ones, and the difference is not cosmetic: insolubles blind filters, and heavy metals carry through to the consumer. Every batch is tested against the full table.

ParameterSpecificationTest method / note
AppearanceWhite to light yellow powderVisual
Al₂O₃ content≥ 29.0%GB 15892, EDTA titration
Basicity40–70%GB 15892; batch value on COA
pH of 1% solution3.5–5.0Glass electrode, 25 °C
Insoluble matter≤ 0.1%Gravimetric; low-turbidity grade ≤ 0.05%
Arsenic (As)≤ 0.0002%ICP-MS
Lead (Pb)≤ 0.001%ICP-MS
Cadmium (Cd)≤ 0.0002%ICP-MS
Mercury (Hg)≤ 0.00001%ICP-MS
Hexavalent chromium (Cr⁶⁺)≤ 0.0005%Spectrophotometric
Shelf life24 months powder / 12 months liquidDry, sealed, 5–35 °C; liquid above 5 °C
Standard: GB 15892 (water treatment chemicals — polyaluminium chloride for drinking water). Produced under a hygiene licence for potable-water contact. We do not hold NSF/ANSI 60 — see the compliance section below before specifying for a US plant.
03 — Mechanism

Same chemistry,
tighter tolerances.

Chemically this is the same pre-hydrolysed aluminium chemistry as the industrial grade. What changes is what is left in the product — and that changes how the plant has to run it.

STEP 01

Al₁₃ forms on dissolution

The powder dissolves into pre-formed polynuclear aluminium species. Because they are already partly neutralised, the coagulant consumes far less alkalinity than alum and does not drag the pH down as far.

STEP 02

Destabilise at low turbidity

In clear or algal water there are few particles and charge neutralisation is the whole job. This is where the potable grade's low insolubles matter: there is no floc blanket to hide behind, and every added particle shows up downstream.

STEP 03

Sweep floc, then control residual Al

At the optimum dose the hydroxide floc enmeshes algae, colour and NOM. Past it, residual aluminium rises — keep filtered water below 0.2 mg/L and hold pH in the 6.5–8 band where the floc is least soluble.

04 — Applications and dose ranges

Where the 29% grade is specified.

Doses are product per cubic metre, as 29% powder. In potable plants the dose is normally set by jar test and confirmed by filtered-water turbidity and residual aluminium, not by the supplier's table.

Surface water plants

River, reservoir and lake water with seasonal turbidity. Removes colour and turbidity and holds filtered water below 0.1 NTU with a conventional train.

10–60 g/m³ · 29% powder

Low-turbidity & algal water

Reservoir water under 5 NTU and algal blooms. The low-insoluble grade avoids the filter blinding that alum causes in these conditions.

5–30 g/m³ · PAC-29 LG

Colour & NOM removal

High-colour upland water and NOM control ahead of chlorination, to cut trihalomethane precursors rather than treat them later.

20–80 g/m³

UF / RO pretreatment

Coagulation ahead of ultrafiltration or reverse osmosis — lowers SDI, extends membrane cleaning intervals and protects the elements.

10–50 g/m³

Food & beverage process water

Potable-standard process water for beverage, dairy and food plants, where the coagulant must meet drinking-water limits by specification.

10–50 g/m³

Municipal wastewater reuse

Tertiary coagulation before filtration and disinfection in reuse schemes, including phosphorus polishing.

20–70 g/m³

Not on the list? The 29% grade is also used for swimming-pool and spa make-up water and for packaged plants in remote communities. For any potable application, tell us the source water and the target turbidity — we will send the batch COA and the licence copy with the quotation.

05 — Preparation and dosing

In potable plants,
the dose is a permit condition.

Everything here is written for a plant that has to demonstrate compliance, not just clear water. Jar test first, dose second, and keep the record.

Make-down and dosing

01Jar test before changing anything. Six doses, 2-minute rapid mix at 200 rpm, 15-minute slow mix at 40 rpm, 30-minute settle. Record turbidity and pH.
02Dissolve to 5–10% w/w in potable-quality water. Use filtered water for make-down; the point of the low-insoluble grade is defeated by dirty dilution water.
03Dilute to 1–5% for dosing. Feed with a metering pump calibrated weekly — a 10% error in dose is a 10% error in residual aluminium.
04Rapid mix 30–60 s at 200–400 rpm. Then flocculate at 20–60 rpm for 10–20 minutes. Short-circuiting here is the usual cause of carry-over.
05Monitor pH and residual aluminium. Target pH 6.5–8.0 and filtered water Al below 0.2 mg/L. If Al climbs while turbidity is fine, you are overdosing.

Five things that quietly ruin performance

Overdosing in clear water. Low-turbidity water has little to floc onto; excess PAC leaves residual aluminium and can raise turbidity rather than lower it.

pH drift out of band. Below pH 6 the floc is less stable; above pH 8 aluminium redissolves as aluminate. Both show up as filtered-water turbidity.

Dirty dilution water. Making down 29% powder in unfiltered river water adds exactly the solids the grade was bought to avoid.

Storage beyond shelf life. Liquid PAC crystallises below 5 °C and segregates in warm storage. Agitate before use and respect the 12-month liquid limit.

Assuming NSF coverage. A hygiene licence is not NSF/ANSI 60. If your specification or state regulator requires NSF, this product does not satisfy it and we will say so before you order.

06 — Packaging and logistics

Packed for a potable supply chain.

25 kg / 50 kg woven bag

PE-lined PP woven bag, 40 bags per pallet or loose in bundles. The standard export packing for both grades.

20–25 t per 20' FCL

1,000 kg jumbo bag

Four-loop FIBC with discharge spout for plants that unload with a hoist and dose from a bulk hopper.

18–20 t per 20' FCL

IBC / drum for liquid

1,000 L IBC or 200 L drum for liquid PAC, with a food-grade liner on the drinking-water grade.

18–20 t per 20' FCL
07 — Compliance

What we hold, and
what we do not.

This is the section a utility procurement officer reads first. Both columns are stated plainly, because a substituted document is worse than a missing one.

✓

Hygiene licence (涉水批件)

Produced under a Chinese hygiene licence for potable-water contact equipment and materials. Copy supplied with quotation.

✓

GB 15892

Tested to the Chinese national standard for polyaluminium chloride used in drinking water.

✓

ISO 9001 / 14001 · SGS

Management systems certified; third-party inspection available per shipment.

✕

No NSF/ANSI 60

We do not hold NSF/ANSI 60. US municipal plants whose specification requires it should not buy this product from us — we will decline rather than substitute a document.

On the standard number. GB 15892 has been revised more than once, and buyers occasionally see an older year on a Chinese COA. Ask for the revision stated on the certificate you are given and check it against your own specification. If your regulator requires NSF/ANSI 60, no Chinese hygiene licence substitutes for it.

08 — Questions buyers actually ask

Before you specify a potable coagulant.

What is the difference between 28% and 29%?

One percentage point of Al₂O₃ and a much tighter specification. The 29% grade has insolubles ≤ 0.1% against ≤ 0.6%, and heavy-metal limits roughly halved, and it is produced under a hygiene licence for potable contact. The industrial grade is not permitted for drinking water.

Do you hold NSF/ANSI 60?

No. We hold a Chinese hygiene licence and produce to GB 15892. If your specification or state regulator requires NSF/ANSI 60, this product does not comply and we will tell you so before quoting rather than after.

What residual aluminium should I expect?

With pH held at 6.5–8.0 and a dose set by jar test, filtered water below 0.2 mg/L is normal, and below 0.1 mg/L is achievable on most surface waters. Persistently higher readings usually mean overdosing or pH drift, not a product problem.

Is it suitable for low-turbidity water?

Yes — use the PAC-29 LG variant with insolubles ≤ 0.05%. In water under 5 NTU the coagulant dose is small and every insoluble particle matters, which is why the standard grade is a poor choice for reservoirs and algal blooms.

Can you supply liquid?

Yes, 10% Al₂O₃ liquid in 1,000 L IBC or 200 L drum with a food-grade liner. Dose is roughly three times the powder per cubic metre. Liquid suits plants above about 5,000 m³/d with lined storage; below that, powder is usually cheaper once freight is counted.

What documents ship with the order?

Batch COA with the full heavy-metal panel, SDS, packing list, certificate of origin, and a copy of the hygiene licence. Legalised or consular documents can be arranged if your customs require them.

Next step

Send the source water.
Get a jar-test protocol and a COA.

Source water, target turbidity, plant flow and your regulator's specification. We reply with a dose range, the batch COA and the licence copy — and we will tell you if your specification names a certification we do not hold.

Reply within 12 working hours · data used for quotation only

Talk to us