Polyaluminium chloride 29%,
for water people actually drink.
[ Al2(OH)nCl6−n ]m · Al₂O₃ ≥ 29% · Insolubles ≤ 0.1%
The drinking-water grade: fewer insolubles, tighter heavy-metal limits, and production under a hygiene licence for potable-water contact. Specified for surface water, low-turbidity and algal water, colour and NOM removal, and membrane pretreatment.
One grade,
two handling options.
Drinking-water duty does not allow a second-best form. Both options below are produced to GB 15892 with the same heavy-metal limits; they differ only in how the plant receives and dissolves them.
All three are produced to GB 15892 and covered by the same hygiene licence for potable-water contact. The licence covers the manufacturing site, not a specific batch — ask for a copy with the quotation and check that the product name on it matches what you are buying.
What the COA will say.
Drinking-water limits are tighter than industrial ones, and the difference is not cosmetic: insolubles blind filters, and heavy metals carry through to the consumer. Every batch is tested against the full table.
| Parameter | Specification | Test method / note |
|---|---|---|
| Appearance | White to light yellow powder | Visual |
| Al₂O₃ content | ≥ 29.0% | GB 15892, EDTA titration |
| Basicity | 40–70% | GB 15892; batch value on COA |
| pH of 1% solution | 3.5–5.0 | Glass electrode, 25 °C |
| Insoluble matter | ≤ 0.1% | Gravimetric; low-turbidity grade ≤ 0.05% |
| Arsenic (As) | ≤ 0.0002% | ICP-MS |
| Lead (Pb) | ≤ 0.001% | ICP-MS |
| Cadmium (Cd) | ≤ 0.0002% | ICP-MS |
| Mercury (Hg) | ≤ 0.00001% | ICP-MS |
| Hexavalent chromium (Cr⁶⁺) | ≤ 0.0005% | Spectrophotometric |
| Shelf life | 24 months powder / 12 months liquid | Dry, sealed, 5–35 °C; liquid above 5 °C |
Same chemistry,
tighter tolerances.
Chemically this is the same pre-hydrolysed aluminium chemistry as the industrial grade. What changes is what is left in the product — and that changes how the plant has to run it.
Al₁₃ forms on dissolution
The powder dissolves into pre-formed polynuclear aluminium species. Because they are already partly neutralised, the coagulant consumes far less alkalinity than alum and does not drag the pH down as far.
Destabilise at low turbidity
In clear or algal water there are few particles and charge neutralisation is the whole job. This is where the potable grade's low insolubles matter: there is no floc blanket to hide behind, and every added particle shows up downstream.
Sweep floc, then control residual Al
At the optimum dose the hydroxide floc enmeshes algae, colour and NOM. Past it, residual aluminium rises — keep filtered water below 0.2 mg/L and hold pH in the 6.5–8 band where the floc is least soluble.
Where the 29% grade is specified.
Doses are product per cubic metre, as 29% powder. In potable plants the dose is normally set by jar test and confirmed by filtered-water turbidity and residual aluminium, not by the supplier's table.
Surface water plants
River, reservoir and lake water with seasonal turbidity. Removes colour and turbidity and holds filtered water below 0.1 NTU with a conventional train.
10–60 g/m³ · 29% powderLow-turbidity & algal water
Reservoir water under 5 NTU and algal blooms. The low-insoluble grade avoids the filter blinding that alum causes in these conditions.
5–30 g/m³ · PAC-29 LGColour & NOM removal
High-colour upland water and NOM control ahead of chlorination, to cut trihalomethane precursors rather than treat them later.
20–80 g/m³UF / RO pretreatment
Coagulation ahead of ultrafiltration or reverse osmosis — lowers SDI, extends membrane cleaning intervals and protects the elements.
10–50 g/m³Food & beverage process water
Potable-standard process water for beverage, dairy and food plants, where the coagulant must meet drinking-water limits by specification.
10–50 g/m³Municipal wastewater reuse
Tertiary coagulation before filtration and disinfection in reuse schemes, including phosphorus polishing.
20–70 g/m³Not on the list? The 29% grade is also used for swimming-pool and spa make-up water and for packaged plants in remote communities. For any potable application, tell us the source water and the target turbidity — we will send the batch COA and the licence copy with the quotation.
In potable plants,
the dose is a permit condition.
Everything here is written for a plant that has to demonstrate compliance, not just clear water. Jar test first, dose second, and keep the record.
Make-down and dosing
Five things that quietly ruin performance
Overdosing in clear water. Low-turbidity water has little to floc onto; excess PAC leaves residual aluminium and can raise turbidity rather than lower it.
pH drift out of band. Below pH 6 the floc is less stable; above pH 8 aluminium redissolves as aluminate. Both show up as filtered-water turbidity.
Dirty dilution water. Making down 29% powder in unfiltered river water adds exactly the solids the grade was bought to avoid.
Storage beyond shelf life. Liquid PAC crystallises below 5 °C and segregates in warm storage. Agitate before use and respect the 12-month liquid limit.
Assuming NSF coverage. A hygiene licence is not NSF/ANSI 60. If your specification or state regulator requires NSF, this product does not satisfy it and we will say so before you order.
Packed for a potable supply chain.
25 kg / 50 kg woven bag
PE-lined PP woven bag, 40 bags per pallet or loose in bundles. The standard export packing for both grades.
20–25 t per 20' FCL1,000 kg jumbo bag
Four-loop FIBC with discharge spout for plants that unload with a hoist and dose from a bulk hopper.
18–20 t per 20' FCLIBC / drum for liquid
1,000 L IBC or 200 L drum for liquid PAC, with a food-grade liner on the drinking-water grade.
18–20 t per 20' FCLWhat we hold, and
what we do not.
This is the section a utility procurement officer reads first. Both columns are stated plainly, because a substituted document is worse than a missing one.
Hygiene licence (涉水批件)
Produced under a Chinese hygiene licence for potable-water contact equipment and materials. Copy supplied with quotation.
GB 15892
Tested to the Chinese national standard for polyaluminium chloride used in drinking water.
ISO 9001 / 14001 · SGS
Management systems certified; third-party inspection available per shipment.
No NSF/ANSI 60
We do not hold NSF/ANSI 60. US municipal plants whose specification requires it should not buy this product from us — we will decline rather than substitute a document.
On the standard number. GB 15892 has been revised more than once, and buyers occasionally see an older year on a Chinese COA. Ask for the revision stated on the certificate you are given and check it against your own specification. If your regulator requires NSF/ANSI 60, no Chinese hygiene licence substitutes for it.
Before you specify a potable coagulant.
What is the difference between 28% and 29%?
One percentage point of Al₂O₃ and a much tighter specification. The 29% grade has insolubles ≤ 0.1% against ≤ 0.6%, and heavy-metal limits roughly halved, and it is produced under a hygiene licence for potable contact. The industrial grade is not permitted for drinking water.
Do you hold NSF/ANSI 60?
No. We hold a Chinese hygiene licence and produce to GB 15892. If your specification or state regulator requires NSF/ANSI 60, this product does not comply and we will tell you so before quoting rather than after.
What residual aluminium should I expect?
With pH held at 6.5–8.0 and a dose set by jar test, filtered water below 0.2 mg/L is normal, and below 0.1 mg/L is achievable on most surface waters. Persistently higher readings usually mean overdosing or pH drift, not a product problem.
Is it suitable for low-turbidity water?
Yes — use the PAC-29 LG variant with insolubles ≤ 0.05%. In water under 5 NTU the coagulant dose is small and every insoluble particle matters, which is why the standard grade is a poor choice for reservoirs and algal blooms.
Can you supply liquid?
Yes, 10% Al₂O₃ liquid in 1,000 L IBC or 200 L drum with a food-grade liner. Dose is roughly three times the powder per cubic metre. Liquid suits plants above about 5,000 m³/d with lined storage; below that, powder is usually cheaper once freight is counted.
What documents ship with the order?
Batch COA with the full heavy-metal panel, SDS, packing list, certificate of origin, and a copy of the hygiene licence. Legalised or consular documents can be arranged if your customs require them.
Send the source water.
Get a jar-test protocol and a COA.
Source water, target turbidity, plant flow and your regulator's specification. We reply with a dose range, the batch COA and the licence copy — and we will tell you if your specification names a certification we do not hold.
One system, not one chemical.
PAC 28% industrial
GB/T 22627-2022 for wastewater, sewage and process duty.
View product →ApplicationMunicipal water
Coagulation, filtration and disinfection — where the coagulant sits in the train.
View application →QualityQuality & certifications
How batches are tested, what the COA contains and which certificates we hold.
View quality →