Home/Resources/Dosage calculator
Free tool · no sign-up

What will it cost
per cubic metre?

Enter the flow and the solids to be removed. The model returns a coagulant dose, a polymer dose with the 1.2× field uplift already applied, daily consumption in kg and the chemical cost per cubic metre. It is a budgeting tool — the jar test still decides.

01 — Estimate

Four inputs,
one cost per m³.

Plant inputs

Prices are indicative export levels — replace them with your quoted price. Freight, labour and sludge disposal are not included.

Result

Coagulant (PAC 28/29%)—
Flocculant (PAM, incl. 1.2×)—
PAC consumption—
PAM consumption—
Solids removed—
Chemical cost—
Chemical cost per m³— —

Dose unit basis for this application: —

02 — The model

How these numbers
are derived.

Published openly so you can check the arithmetic and correct it for your own plant.

Coagulant dose scales with the solids that actually have to be removed, not with the influent figure. A plant removing 30 mg/L and a plant removing 300 mg/L are not doing the same job, even at the same flow.

The calculator uses a linear-with-offset model for coagulant — PAC (g/m³) = 0.18 × solids removed (mg/L) + 8 — clamped to the published range for each application. Polymer dose is derived from the coagulant dose, because the polymer's job is to bridge what the coagulant destabilised: PAM = 0.012 × PAC + 0.35, then multiplied by 1.2 for field conditions.

Two applications override the default: mining and sludge dewatering are solids-basis duties, where the polymer dose tracks solids removed rather than PAC, and paper is driven by production tonnage rather than flow.

Where the model is wrong

It does not know your particle size distribution, alkalinity, mixing energy or sludge age. Those four move the real optimum by up to ±40%.

It also cannot tell you whether the product is compliant for your market. A calculator output is not a specification.

Use it to size a trial and to sanity-check a quotation — then run the jar test. We will run it for you at no charge.

Send a sample for testing
03 — Questions

About the numbers.

How accurate is this calculator?

It is a budgeting tool, not a design basis. The model scales coagulant dose with the solids to be removed and derives the polymer dose from the coagulant dose, then applies a 1.2× field uplift to the polymer only. Real optima vary by ±40% with particle size, alkalinity and mixing energy, so use the output to size a trial, then run a jar test.

Why is the PAM dose multiplied by 1.2?

Because field consumption is consistently higher than bench figures — solution losses, overdosing to chase clarity, and the difference between a beaker and a plant. We apply the uplift to polymer only; PAC doses are not uplifted.

What does the cost figure include?

Chemical only, at the unit prices you enter. It excludes freight, labour, make-down power and sludge disposal, which together often exceed the chemical cost. Treat it as the floor, not the budget.

Can I use it for drinking water?

Use the municipal preset, but note that potable dosing is a permit condition set by jar test, not by a calculator. The model also cannot check that the product you choose is a drinking-water grade — that is a compliance decision.

How do I convert g/m³ to bags or containers?

1 g/m³ equals 1 mg/L and equals 1 kg per 1,000 m³. So a 60 g/m³ dose at 10,000 m³/d is 600 kg/day, or 24 bags of 25 kg, or about 18 t a month.

Talk to us