Paper: retention economics,
measured in fibre and steam.
Every tonne of fibre that goes out with the white water is a tonne bought twice. The retention program decides how much of it stays in the sheet — and it is usually the cheapest upgrade available to a mill that has already optimised the machine.
What goes into this water
What the wet end
actually tells you.
Paper is the most instrumented customer group we sell to — there is data everywhere. These are the figures that decide whether a retention program will work or be fought by the chemistry of the furnish.
| Parameter | Typical range | Why it matters |
|---|---|---|
| Furnish pH | 4.5–8.0 | Acidic sizing runs need a different cationic demand and often a non-ionic grade |
| Conductivity | 500–5,000 µS/cm | High closure raises anionic trash and consumes cationic polymer before it reaches the fibre |
| Filler content | 10–30% | Filler has more surface area per gram than fibre, so it sets the polymer demand |
| Consistency at headbox | 0.5–1.2% | Dose is per tonne of paper, but mixing quality depends on consistency |
| White water TSS | 200–2,000 ppm | The number that shows whether retention is actually working |
| Cationic demand | 50–600 µmol/L | The single best predictor of fixing-agent dose; measure it, do not guess |
Where the chemicals go.
Retention chemistry is sequential: fix the trash, then bridge the fines. Reverse the order and both doses rise.
On a closed mill the loop water carries the anionic trash back to the headbox, so the fixing-agent dose creeps up as closure increases. Budget for that when a mill moves to higher closure — it is not a polymer problem.
Three products, one sequence.
Most mills need a fixing agent and one retention aid; the third product is for the save-all or the sludge line.
PAC 28% industrial
Neutralises dissolved and colloidal anionic trash so the cationic retention aid can reach the fibre instead of being consumed by the water.
2–8 kg/t paper →RetentionCationic PAM C10 / C30
Charge density matched to the furnish. C10 for woodfree and low-trash furnishes, C30 for high-trash or high-closure systems.
0.2–1.0 kg/t →White waterAnionic PAM A1010
Save-all clarification and fibre recovery. Lower MW than a tailings grade — you want fast floc, not the longest chain.
0.3–1.2 kg/t →On the trial. A retention trial needs a machine trial, not a beaker: we ask for furnish, white water and the current chemical program, then supply samples with a dosing plan that the machine tender can actually follow on a shift.
Dose reference.
Per tonne of paper unless stated. Retention doses are small and the make-down accuracy matters more than the grade choice at the margin.
| Duty | Product | Dose | Target |
|---|---|---|---|
| Fixing agent (woodfree) | PAC 28% | 2–5 kg/t | Cationic demand reduced to < 50 µmol/L |
| Fixing agent (high trash) | PAC 28% | 5–8 kg/t | Stable first-pass retention |
| Retention aid | Cationic C10 / C30 | 0.2–0.6 kg/t | First-pass retention > 85% |
| White water / save-all | Anionic A1010 | 0.3–1.0 kg/t | White water TSS < 100 ppm |
| Broke recovery | Anionic A1010 | 0.5–1.2 kg/t | Clear save-all filtrate |
| Primary sludge dewatering | Cationic C50 | 3–6 kg/t DS | Cake 25–32% DS |
Why retention programs stall.
Four patterns we see repeatedly on machines that have already tried a retention aid and been disappointed.
Polymer consumed by trash
Without a fixing agent the cationic polymer is neutralised by dissolved anionic material before it reaches the fines. The mill concludes the polymer is weak; the real problem is sequencing.
Wrong shear point
Adding retention aid before the fan pump exposes it to the highest shear on the machine. Dose after the pump, before the headbox, and accept that some chain breakage is inevitable.
Under-hydrated solution
Retention doses are small, so a badly made-down solution is a large percentage error. Make down at 0.1–0.3% and check for gel particles weekly.
Ignoring closure effects
As the mill closes up, conductivity and anionic trash rise and the optimum dose moves. A program that worked at 60% closure may need a higher-charge grade at 90%.
Before the machine trial.
Can you match the retention aid we already use?
Usually. Send the current TDS and a sample of furnish and white water; we run a focused trial on cationic demand, turbidity and drainage (SR or DFR) and compare against your existing product at equal cost per tonne.
Is a fixing agent always necessary?
No. Mills with low conductivity and clean furnish often run a retention aid alone. Above roughly 1,500 µS/cm or with high anionic trash, a PAC fixing step usually pays for itself in reduced polymer consumption.
What about neutral and acid sizing?
Acid systems at pH 4.5–5.5 often need a non-ionic PAM because the cationic demand profile is different and alum already provides the charge. We supply non-ionic grades for that case.
How is the product delivered to a paper mill?
25 kg bags on pallets, or 750 kg jumbos for bulk make-down. Most mills take a mixed container: PAC in 25 kg bags, PAM in 750 kg jumbos. Lead time from stock is 7–10 days.
Do you supply deinking mills?
Yes — PAC plus a cationic or anionic PAM depending on the ink system, and cationic PAM for the deinking sludge. Send the furnish mix and the clarifier load; deinking pulp has a higher anionic demand than virgin fibre.
Send the furnish and white water.
Get a retention plan.
Furnish mix, pH, conductivity, cationic demand and current retention figure. We reply with a program, a dose range and a machine-trial plan that a shift supervisor can run.