Mining: the water you get back
decides the cost per tonne.
A tailings thickener is a water-recovery device that happens to handle solids. We supply the coagulant and the flocculant as one matched pair — tested on your ore and your process water — so underflow density and overflow clarity move together instead of trading off against each other.
What goes into this water
Four numbers decide
which grade you need.
We ask for these before quoting, because a grade recommendation without them is a guess. Most mines can produce all four from the metallurgical balance and a water analysis.
| Parameter | Typical range | Why it decides the grade |
|---|---|---|
| Solids content of feed | 15–45% w/w | Sets the PAM dose per tonne and whether a thickener or a paste thickener is the right device |
| pH of the slurry | 2–11 | Below pH 5 anionic PAM protonates and coils — that single fact moves the duty to non-ionic |
| Calcium + magnesium | 50–800 mg/L | Hardness ions help destabilise, so hard water needs less PAC and tolerates a lower-charge PAM |
| Particle size (P80) | 30–150 µm | Fine grinding means more surface area, more polymer and a slower-settling floc |
| Clay / slime fraction | 5–35% | Clays hold water and blind filters; they dictate whether a coagulant is needed at all |
| Water recycle ratio | 70–95% | Recycled water accumulates fines and reagents, which changes the optimum dose week to week |
Where each chemical sits.
Dosing in the wrong place is the most common reason a mine concludes the polymer “doesn't work”. The sequence below is the one that survives contact with a real plant.
The two mixing energies matter as much as the chemicals: PAC needs violent mixing for less than a minute, PAM needs gentle mixing for one to two minutes. Put both in the same pipe and neither works.
The program, matched to the duty.
Three products cover almost every mine water we see. Most plants need two of them, not three.
PAC 28% industrial
GB/T 22627-2022. Neutralises the clay and slime charge so the polymer has somewhere to attach. Without it, anionic PAM on a stable slime suspension is money down the drain.
30–150 g/t solids →FlocculantAnionic PAM A1210 / A1610
MW 12–18 million, hydrolysis 20–30 mol%. A1210 for conventional thickener feed, A1610 when overflow still carries fines or the underflow is short of density.
20–80 g/t solids →Acid dutyNon-ionic PAM N06
Hydrolysis ≤ 5 mol%. Specified when the circuit runs below pH 5 — acid leach CCD, some coal wash water — where anionic chemistry stops bridging.
30–120 g/t solids →How we start. A jar test on your own slurry, run as a dose ladder for PAC and then for PAM, with settling rate, overflow turbidity and underflow density recorded at each point. You get the curves, not just a recommendation — so the plant can re-optimise when the ore changes.
Dose reference by duty.
Figures are product per tonne of dry solids and already include the uplift we apply to textbook values to reflect plant practice. They are starting points for a jar test, not a design basis.
| Duty | Coagulant | Flocculant | Target |
|---|---|---|---|
| Iron ore tailings | PAC 30–80 g/t | A1210 25–60 g/t | Overflow < 300 NTU, underflow 65–70% |
| Copper / lead-zinc tailings | PAC 40–120 g/t | A1610 30–70 g/t | Overflow < 250 NTU, underflow 68–72% |
| Gold CIL / CCD | PAC 30–100 g/t | A1610 25–60 g/t | Clarified overflow < 50 NTU for carbon circuits |
| Acid leach CCD (pH < 3) | — | N06 40–120 g/t | Overflow < 200 NTU without pH adjustment |
| Coal wash water | PAC 20–60 g/t | A1010 15–50 g/t | Recycle water < 100 NTU |
| Concentrate filtration | — | A1210 10–40 g/t | Cake moisture down 2–4 points |
Why a thickener stops working.
Four failures that account for most of the calls we get from mineral processing plants.
Overdosing the flocculant
Beyond the optimum the excess polymer re-stabilises the fines and overflow turbidity climbs while the bed gets mushy. If clarity worsens as dose rises, you are past the peak — cut 20% and re-run the ladder.
Single-point dosing into high shear
A centrifugal pump or a raw feed launder destroys the floc before it reaches the feedwell. Post-dilute to 0.05–0.1% and inject where the energy is under G 100 s⁻¹.
Ignoring the water chemistry
Hardness, sulfate and residual reagents from the mill all change the optimum. A grade that worked in July can underperform in December on the same ore.
Running without a coagulant
On clay-rich slimes, anionic PAM alone cannot adsorb — the surfaces are already negative. PAC first is not an upsell, it is the mechanism.
Before you run the jar test.
Can you match a competitor's product we are already using?
Usually, and we prefer to try. Send the current product's TDS or a 200 g sample plus your slurry; we run both side by side on the same ladder and report settling rate, overflow turbidity and underflow density. If ours is not better, we will say so.
Do we need both PAC and PAM?
On clay-rich or fine-ground slurries, yes. On clean, coarse, high-hardness tailings, anionic PAM alone often reaches target. The jar test answers this in an afternoon and the answer is worth real money over a year.
What about acid circuits below pH 3?
Use non-ionic PAM. Anionic PAM's carboxylate groups protonate at that pH, the chain coils, and bridging stops. Adjusting pH to suit a cheaper polymer costs more in lime than the polymer saves.
How does the trial work?
Free 500 g samples and a written ladder protocol. A 1 t trial order follows, then 20–25 t per container. Most mines go from sample to container in six to ten weeks, including the internal approval.
Can you supply to site, not just to port?
We quote FOB, CIF and DDP. Where we have a forwarder we deliver to site and handle customs; where we do not, we name the nearest port and work with your broker.
Send the slurry data.
Get a dose curve.
Solids content, pH, calcium and magnesium, P80 and your current thickener performance. With a 2-litre sample we return a ladder test report and a recommended grade.