Anionic polyacrylamide,
specified by number, not by adjective.
[ CH2–CH(COO−M+) ]n · MW 5–22 × 10⁶ · Hydrolysis 5–40 mol%
A bridging flocculant for negatively charged solids — mineral tailings, coal wash water, sand and aggregate, paper furnish. We publish molecular weight, hydrolysis degree and monomer limit for every grade, and confirm the one that fits your slurry on a jar test before you commit to a container.
Four grades cover
most of the anionic market.
Molecular weight sets the bridging length; hydrolysis sets how much negative charge the chain carries. Those two numbers decide whether a polymer works on your slurry, so we hold four combinations in stock instead of quoting “high molecular weight” and hoping.
Viscosity figures are typical for a 0.1% solution in deionised water at 25 °C, Brookfield LV, 60 rpm. Hydrolysis can be adjusted between 5 and 40 mol% on request; the four grades above are the ones we keep in stock for immediate shipment.
What the COA will say.
Every batch ships with a certificate of analysis carrying these parameters. If a figure matters to your process and it is not on this list, ask — most of them can be added to the routine test schedule.
| Parameter | Specification | Test method / note |
|---|---|---|
| Appearance | White to off-white granules | Visual, GB/T 17514-2017 |
| Solid content | ≥ 90% | Drying at 105 °C to constant weight |
| Molecular weight | 5–22 × 10⁶ | Intrinsic viscosity, GB/T 17514-2017 |
| Degree of hydrolysis | 5–40 mol% | Titration; grade-specific value stated on COA |
| Residual acrylamide monomer | ≤ 0.1% | Industrial grade. Drinking-water grade ≤ 0.025% on request |
| Insoluble matter | ≤ 0.2% | Filtration of 0.1% solution |
| pH of 0.1% solution | 6–8 | Glass electrode, 25 °C |
| Dissolution time | 30–75 min | 0.1–0.3% concentration, 25 °C, 60 rpm |
| Bulk density | 0.6–0.8 g/cm³ | Loose bulk, as packed |
| Particle size | 90% within 20–80 mesh | Sieve analysis; other cuts on request |
| Shelf life | 24 months | Unopened bag, dry, below 35 °C, out of sunlight |
Why an anionic chain needs
a coagulant in front of it.
Anionic PAM is a bridging polymer, not a coagulant. Understanding the sequence explains most of the “the polymer didn't work” complaints we get from plants that were dosing it alone.
Stable suspension
Particles carry a negative surface charge and repel each other. A long anionic chain cannot adsorb onto them — same charge, no attraction. Dosing more polymer just puts more unadsorbed polymer in the water.
Destabilise with PAC or Ca²⁺
PAC hydrolyses to cationic species that neutralise the surface charge; hardness ions do the same job in tailings water. Once the charge is reduced, the particle surface has room for the polymer to attach.
Bridge into a floc
One chain adsorbs on several particles at once and pulls them into a floc large enough to settle or to dewater. Overdosing or pumping shear breaks the chain mid-backbone — which is why the dosing point and the pump matter as much as the grade.
Where anionic PAM earns its cost.
Dose figures below are product per unit of feed, already adjusted upward from textbook values to reflect what plants actually consume. Treat them as a starting point for a jar test, not a design basis.
Mineral tailings thickening
Iron, copper, lead-zinc, gold and phosphate tailings. Improves underflow density and overflow clarity in conventional and paste thickeners.
20–80 g/t solids · grades A1210 / A1610Coal washing
Slurry water clarification and fine coal recovery. Works alongside PAC where clay content is high.
15–50 g/t solids · grades A1010 / A1210Enhanced oil recovery
Polymer flooding and profile control in high-salinity reservoirs. Requires the high-MW, moderate-hydrolysis grade and a screened brine.
1,000–2,500 mg/L in slug · grade A1610Paper retention & white water
Fines and filler retention, plus clarification of white water. Usually paired with a cationic coagulant upstream.
0.3–1.5 kg/t paper · grades A1010 / A1210Textile & dyeing wastewater
Colour and suspended solids removal after PAC decolourisation; shortens settling time in the equalisation tank.
5–20 ppm · grades A1210 / A1610Sand, aggregate & tunnelling
Wash water recycling and slurry dewatering in sand plants, ready-mix reclaimers and TBM slurry separation.
10–40 g/t solids · grade A1010Not on the list? Anionic PAM also runs in sugar juice clarification, food processing wash water, and as a soil conditioner. Send us the suspended solids, pH, and the cations in your water — calcium and magnesium content changes the answer more than most buyers expect.
Most polymer failures
happen at the make-down skid.
The powder is only half the product. Solution strength, mixing energy and residence time decide whether the chain arrives at the feed point intact.
Make-down procedure
Five things that quietly ruin performance
Iron and copper contact. Rust and copper ions catalyse chain scission. Use PVC, PP or stainless lines and tanks.
Centrifugal pumps. A progressive-cavity or diaphragm pump at low speed preserves molecular weight; a centrifugal transfer pump can take a grade A2010 down to A1210 behaviour.
Hard mixing water. Very high calcium water shortens hydration; soften or use process water where possible.
Overdosing. Beyond the optimum, the excess polymer re-stabilises the particles and the water gets worse. If clarity drops as dose rises, you are past the optimum.
Freezing or damp storage. Bags that take on moisture form lumps that never dissolve. Keep them on pallets, off concrete, below 35 °C.
Loaded to the port you name.
25 kg woven bag
PE-lined PP woven bag with inner liner, 40 bags per pallet or 40 loose bags per bundle.
20–25 t per 20' FCL750 kg jumbo bag
Four-loop FIBC with discharge spout, for plants with bulk hoppers and no manual handling.
18–20 t per 20' FCLTerms and documents
FOB Shanghai / Qingdao, CIF, or DDP where we have a forwarder. COA, SDS, packing list and certificate of origin included.
Non-hazardous cargo · no DG declarationWhat we hold, and
what we do not.
Buyers in regulated markets need to know the difference before they write a specification. So we state both sides.
GB/T 17514-2017
Produced and tested to the Chinese national standard for water-treatment polyacrylamide.
ISO 9001 / 14001
Quality and environmental management certified across the production sites.
SGS / CCIC
Third-party inspection available per shipment, at buyer's request and cost.
No NSF/ANSI 60
We do not hold it. For US municipal drinking water requiring that certification, we decline the enquiry rather than substitute a document.
On the monomer limit. Industrial grade is ≤ 0.1% residual acrylamide. A drinking-water grade at ≤ 0.025% is produced on request — but it is a separate production run with its own lead time, not an upgrade you can add after the order is placed.
Before you specify a grade.
Anionic or cationic — how do I choose?
Let the charge of your solids decide. Mineral tailings, coal slurry, sand wash water and metal hydroxide sludge are negatively charged and take anionic PAM. Organic sludge from municipal or biological treatment is positively charged and takes cationic. Charge density and molecular weight are then fixed on a jar test — no catalogue can tell you the right number for your water.
Does anionic PAM work without a coagulant?
Usually not well. On a stable, strongly negative suspension the anionic chain cannot adsorb, so performance stays poor no matter how much you dose. The normal arrangement is PAC or a multivalent cation first, anionic PAM second — roughly 20–150 ppm PAC followed by 0.5–3 ppm PAM.
Which molecular weight for tailings thickening?
Start at 12–14 million for conventional thickener feed. Move to 16–18 million when overflow still carries fines or underflow density is short of target. Above 18 million, solution viscosity rises fast — longer dissolution, more shear degradation in the dosing line. Above 20 million is normally only justified for high-solid tailings and oil sands.
What is the MOQ, and can I test before buying?
Free 500 g samples for jar testing, couriered at our cost for qualified projects. Trial orders start at 1 ton (40 × 25 kg bags). A 20-foot container holds 20–25 tons depending on palletisation and destination requirements.
Is a drinking-water grade available?
Yes, on request — produced to the drinking-water limits of GB/T 17514-2017 with residual acrylamide at or below 0.025%. Note that we do not hold NSF/ANSI 60, so we do not offer product to US municipal drinking-water plants that require that certification.
How long does it keep, and how is it dissolved?
24 months from production date in the unopened bag, stored dry below 35 °C out of sunlight. Dissolve at 0.1–0.3% — disperse at 400–800 rpm, hydrate at ~60 rpm for 40–60 minutes, use within 24 hours. Keep solution away from iron and copper, and never add powder into a high-shear pump inlet.
Send the slurry data.
Get a grade, not a brochure.
Tell us the feed solids, pH, water hardness and what the thickener is currently doing wrong. We reply with a grade recommendation, a dose range, and a sample dispatch date.
One system, not one chemical.
Cationic polyacrylamide
10–80 mol% charge for organic sludge dewatering and paper retention.
View product →CoagulantPAC 28% industrial
GB/T 22627-2022. Destabilises the colloids your PAM then bridges.
View product →ToolDosage calculator
Estimate PAC and PAM demand from flow rate, suspended solids and process type.
Open calculator →