Home/Products/Anionic polyacrylamide
GB/T 17514-2017 · Four standard grades

Anionic polyacrylamide,
specified by number, not by adjective.

[ CH2–CH(COO−M+) ]n  ·  MW 5–22 × 10⁶  ·  Hydrolysis 5–40 mol%

A bridging flocculant for negatively charged solids — mineral tailings, coal wash water, sand and aggregate, paper furnish. We publish molecular weight, hydrolysis degree and monomer limit for every grade, and confirm the one that fits your slurry on a jar test before you commit to a container.

4STANDARD GRADES
5–22 MMOLECULAR WEIGHT
≤0.1%RESIDUAL MONOMER
24 moSHELF LIFE
CH₂
CH
COO⁻
CH₂
CH
COO⁻
CH₂
CH
COO⁻
CH₂
Anionic repeat unit — [CH₂–CH(COO⁻M⁺)]n · M = Na⁺ / K⁺
01 — Grade range

Four grades cover
most of the anionic market.

Molecular weight sets the bridging length; hydrolysis sets how much negative charge the chain carries. Those two numbers decide whether a polymer works on your slurry, so we hold four combinations in stock instead of quoting “high molecular weight” and hoping.

HQ-A1010
8–10M
Molecular weight
Hydrolysis20–25 mol%
Dissolution30–40 min
Solution 0.1%~250 mPa·s
Coal washing, sand and aggregate wash water, low-shear dosing lines.
HQ-A1210
12–14M
Molecular weight
Hydrolysis20–25 mol%
Dissolution40–50 min
Solution 0.1%~420 mPa·s
General tailings thickening — the default starting point for new projects.
HQ-A1610
16–18M
Molecular weight
Hydrolysis25–30 mol%
Dissolution50–60 min
Solution 0.1%~680 mPa·s
Iron and copper tailings, fine overflow carrying solids, EOR profile control.
HQ-A2010
18–22M
Molecular weight
Hydrolysis25–30 mol%
Dissolution60–75 min
Solution 0.1%~900 mPa·s
High-solid tailings, oil sands, thickener underflow density campaigns.

Viscosity figures are typical for a 0.1% solution in deionised water at 25 °C, Brookfield LV, 60 rpm. Hydrolysis can be adjusted between 5 and 40 mol% on request; the four grades above are the ones we keep in stock for immediate shipment.

02 — Technical data

What the COA will say.

Every batch ships with a certificate of analysis carrying these parameters. If a figure matters to your process and it is not on this list, ask — most of them can be added to the routine test schedule.

ParameterSpecificationTest method / note
AppearanceWhite to off-white granulesVisual, GB/T 17514-2017
Solid content≥ 90%Drying at 105 °C to constant weight
Molecular weight5–22 × 10⁶Intrinsic viscosity, GB/T 17514-2017
Degree of hydrolysis5–40 mol%Titration; grade-specific value stated on COA
Residual acrylamide monomer≤ 0.1%Industrial grade. Drinking-water grade ≤ 0.025% on request
Insoluble matter≤ 0.2%Filtration of 0.1% solution
pH of 0.1% solution6–8Glass electrode, 25 °C
Dissolution time30–75 min0.1–0.3% concentration, 25 °C, 60 rpm
Bulk density0.6–0.8 g/cm³Loose bulk, as packed
Particle size90% within 20–80 meshSieve analysis; other cuts on request
Shelf life24 monthsUnopened bag, dry, below 35 °C, out of sunlight
Standard: GB/T 17514-2017 (water treatment chemicals — polyacrylamide). Third-party inspection by SGS or CCIC can be arranged at buyer's request and cost. TDS, SDS and a sample COA are available before order.
03 — Mechanism

Why an anionic chain needs
a coagulant in front of it.

Anionic PAM is a bridging polymer, not a coagulant. Understanding the sequence explains most of the “the polymer didn't work” complaints we get from plants that were dosing it alone.

STEP 01

Stable suspension

Particles carry a negative surface charge and repel each other. A long anionic chain cannot adsorb onto them — same charge, no attraction. Dosing more polymer just puts more unadsorbed polymer in the water.

STEP 02

Destabilise with PAC or Ca²⁺

PAC hydrolyses to cationic species that neutralise the surface charge; hardness ions do the same job in tailings water. Once the charge is reduced, the particle surface has room for the polymer to attach.

STEP 03

Bridge into a floc

One chain adsorbs on several particles at once and pulls them into a floc large enough to settle or to dewater. Overdosing or pumping shear breaks the chain mid-backbone — which is why the dosing point and the pump matter as much as the grade.

04 — Applications and dose ranges

Where anionic PAM earns its cost.

Dose figures below are product per unit of feed, already adjusted upward from textbook values to reflect what plants actually consume. Treat them as a starting point for a jar test, not a design basis.

Mineral tailings thickening

Iron, copper, lead-zinc, gold and phosphate tailings. Improves underflow density and overflow clarity in conventional and paste thickeners.

20–80 g/t solids · grades A1210 / A1610

Coal washing

Slurry water clarification and fine coal recovery. Works alongside PAC where clay content is high.

15–50 g/t solids · grades A1010 / A1210

Enhanced oil recovery

Polymer flooding and profile control in high-salinity reservoirs. Requires the high-MW, moderate-hydrolysis grade and a screened brine.

1,000–2,500 mg/L in slug · grade A1610

Paper retention & white water

Fines and filler retention, plus clarification of white water. Usually paired with a cationic coagulant upstream.

0.3–1.5 kg/t paper · grades A1010 / A1210

Textile & dyeing wastewater

Colour and suspended solids removal after PAC decolourisation; shortens settling time in the equalisation tank.

5–20 ppm · grades A1210 / A1610

Sand, aggregate & tunnelling

Wash water recycling and slurry dewatering in sand plants, ready-mix reclaimers and TBM slurry separation.

10–40 g/t solids · grade A1010

Not on the list? Anionic PAM also runs in sugar juice clarification, food processing wash water, and as a soil conditioner. Send us the suspended solids, pH, and the cations in your water — calcium and magnesium content changes the answer more than most buyers expect.

05 — Preparation and dosing

Most polymer failures
happen at the make-down skid.

The powder is only half the product. Solution strength, mixing energy and residence time decide whether the chain arrives at the feed point intact.

Make-down procedure

01Dilute to 0.1–0.3% w/w. 1–3 kg powder per m³ of water. Thicker solutions are hard to meter and shear-degrade in the pump.
02Disperse at 400–800 rpm. Add powder into the vortex, never onto the surface — that is how you get fish-eyes that never dissolve.
03Hydrate at ~60 rpm for 40–60 min. High-MW grades need the upper end. An under-hydrated solution performs like a lower grade.
04Use within 24 hours. Activity decays with time and bacterial load; do not let solution sit over a weekend.
05Dose downstream of the coagulant. Give PAC 30–90 seconds of contact before the polymer sees the water, and keep the injection point out of high-shear zones.

Five things that quietly ruin performance

Iron and copper contact. Rust and copper ions catalyse chain scission. Use PVC, PP or stainless lines and tanks.

Centrifugal pumps. A progressive-cavity or diaphragm pump at low speed preserves molecular weight; a centrifugal transfer pump can take a grade A2010 down to A1210 behaviour.

Hard mixing water. Very high calcium water shortens hydration; soften or use process water where possible.

Overdosing. Beyond the optimum, the excess polymer re-stabilises the particles and the water gets worse. If clarity drops as dose rises, you are past the optimum.

Freezing or damp storage. Bags that take on moisture form lumps that never dissolve. Keep them on pallets, off concrete, below 35 °C.

06 — Packaging and logistics

Loaded to the port you name.

25 kg woven bag

PE-lined PP woven bag with inner liner, 40 bags per pallet or 40 loose bags per bundle.

20–25 t per 20' FCL

750 kg jumbo bag

Four-loop FIBC with discharge spout, for plants with bulk hoppers and no manual handling.

18–20 t per 20' FCL

Terms and documents

FOB Shanghai / Qingdao, CIF, or DDP where we have a forwarder. COA, SDS, packing list and certificate of origin included.

Non-hazardous cargo · no DG declaration
07 — Compliance

What we hold, and
what we do not.

Buyers in regulated markets need to know the difference before they write a specification. So we state both sides.

✓

GB/T 17514-2017

Produced and tested to the Chinese national standard for water-treatment polyacrylamide.

✓

ISO 9001 / 14001

Quality and environmental management certified across the production sites.

✓

SGS / CCIC

Third-party inspection available per shipment, at buyer's request and cost.

✕

No NSF/ANSI 60

We do not hold it. For US municipal drinking water requiring that certification, we decline the enquiry rather than substitute a document.

On the monomer limit. Industrial grade is ≤ 0.1% residual acrylamide. A drinking-water grade at ≤ 0.025% is produced on request — but it is a separate production run with its own lead time, not an upgrade you can add after the order is placed.

08 — Questions buyers actually ask

Before you specify a grade.

Anionic or cationic — how do I choose?

Let the charge of your solids decide. Mineral tailings, coal slurry, sand wash water and metal hydroxide sludge are negatively charged and take anionic PAM. Organic sludge from municipal or biological treatment is positively charged and takes cationic. Charge density and molecular weight are then fixed on a jar test — no catalogue can tell you the right number for your water.

Does anionic PAM work without a coagulant?

Usually not well. On a stable, strongly negative suspension the anionic chain cannot adsorb, so performance stays poor no matter how much you dose. The normal arrangement is PAC or a multivalent cation first, anionic PAM second — roughly 20–150 ppm PAC followed by 0.5–3 ppm PAM.

Which molecular weight for tailings thickening?

Start at 12–14 million for conventional thickener feed. Move to 16–18 million when overflow still carries fines or underflow density is short of target. Above 18 million, solution viscosity rises fast — longer dissolution, more shear degradation in the dosing line. Above 20 million is normally only justified for high-solid tailings and oil sands.

What is the MOQ, and can I test before buying?

Free 500 g samples for jar testing, couriered at our cost for qualified projects. Trial orders start at 1 ton (40 × 25 kg bags). A 20-foot container holds 20–25 tons depending on palletisation and destination requirements.

Is a drinking-water grade available?

Yes, on request — produced to the drinking-water limits of GB/T 17514-2017 with residual acrylamide at or below 0.025%. Note that we do not hold NSF/ANSI 60, so we do not offer product to US municipal drinking-water plants that require that certification.

How long does it keep, and how is it dissolved?

24 months from production date in the unopened bag, stored dry below 35 °C out of sunlight. Dissolve at 0.1–0.3% — disperse at 400–800 rpm, hydrate at ~60 rpm for 40–60 minutes, use within 24 hours. Keep solution away from iron and copper, and never add powder into a high-shear pump inlet.

Next step

Send the slurry data.
Get a grade, not a brochure.

Tell us the feed solids, pH, water hardness and what the thickener is currently doing wrong. We reply with a grade recommendation, a dose range, and a sample dispatch date.

Reply within 12 working hours · data used for quotation only

Talk to us