Home/Products/Cationic polyacrylamide
GB/T 31246 · Four charge densities

Cationic polyacrylamide,
matched to your sludge, not to a price list.

[ CH2–CH(CONH2) ]n–[ CH2–CH(N+R3Cl−) ]m  ·  Charge 10–80 mol%  ·  MW 6–12 × 10⁶

A cationic flocculant for negatively charged sludge and colloids — municipal biological sludge, DAF float, paper furnish, dyeing effluent. On a belt press or a centrifuge, charge density decides whether the floc survives; we publish it for every grade and confirm it on your own sludge before you commit to a container.

4CHARGE DENSITIES
10–80mol% CHARGE
≤0.10%RESIDUAL MONOMER
24 moSHELF LIFE
CH₂
CH
N⁺R₃
CH₂
CH
N⁺R₃
CH₂
CH
N⁺R₃
CH₂
Cationic repeat unit — [CH₂–CH(N⁺R₃Cl⁻)]m · R = CH₃ / C₂H₅
01 — Grade range

Charge density first,
molecular weight second.

On organic sludge the floc has to survive 1–3 minutes of shear inside a centrifuge or between belt press rollers. Bigger molecules do not help with that — charge density does. Our grade number after the C is the nominal charge density in mol%.

HQ-C10
10mol%
Charge density
Molecular weight8–10 M
Dissolution35–45 min
Best forMixed sludge, belt press
Light, shear-tolerant floc for belt presses and low-speed centrifuges on mixed or lightly digested sludge.
HQ-C30
30mol%
Charge density
Molecular weight10–12 M
Dissolution40–50 min
Best forActivated sludge, DAF
The general-purpose grade — activated sludge, DAF float, screw press. Start here if you have no jar-test data.
HQ-C50
50mol%
Charge density
Molecular weight8–10 M
Dissolution40–50 min
Best forDigested sludge, centrifuge
Anaerobically digested and high-organic sludge where a low charge density leaves the cake wet.
HQ-C80
80mol%
Charge density
Molecular weight6–8 M
Dissolution30–40 min
Best forColour, food, high charge
High-charge duties: dyeing and printing effluent, food processing, and colloids that resist lower-charge polymers.

Charge density is nominal and measured by colloid titration; the COA states the batch value. Molecular weight is quoted as viscosity-average. A grade outside this range — 20, 40, 60, 70 mol% — can be produced to order at 5 t minimum.

02 — Technical data

What the COA will say.

Cationic PAM is specified by charge density, molecular weight and residual monomer. Everything else on this table is there because a plant asked for it at some point.

ParameterSpecificationTest method / note
AppearanceWhite granules or powderVisual
Solid content≥ 90%Drying at 105 °C to constant weight
Charge density10–80 mol%Colloid titration; grade-specific value on COA
Molecular weight6–12 × 10⁶Intrinsic viscosity
Residual acrylamide monomer≤ 0.10%GB/T 31246
Insoluble matter≤ 0.2%Filtration of 0.1% solution
pH of 0.1% solution4–7Glass electrode, 25 °C
Dissolution time30–50 min0.1–0.5% concentration, 25 °C, 60 rpm
Bulk density0.6–0.8 g/cm³Loose bulk, as packed
Shelf life24 monthsUnopened bag, dry, below 35 °C, out of sunlight
Standard: GB/T 31246 (water treatment chemicals — cationic polyacrylamide). Cationic PAM hydrates faster than anionic, so a 30–50 minute make-down is normally enough. TDS, SDS and a sample COA are available before order.
03 — Mechanism

Two jobs at once —
neutralise, then bridge.

Cationic PAM is the only one of the three families that both neutralises charge and bridges. That is why it works on sludge without a coagulant, and why its optimum dose window is narrower than anionic.

STEP 01

Negatively charged sludge

Biological sludge, DAF float and most organic colloids carry a negative surface charge. Water is bound to that surface, which is why the sludge is bulky and the cake is wet: the polymer has to release that water before the press can.

STEP 02

Adsorb and neutralise

Cationic groups attach to the negative surface and neutralise it locally. Dosage is critical: too little leaves the charge intact, too much reverses it and the sludge re-stabilises — the classic “more polymer, worse cake” symptom.

STEP 03

Bridge into a pressable floc

Loops and tails bridge neighbouring particles into a floc that releases free water and holds together under shear. For dewatering, a compact and tough floc beats a large fragile one — which is why charge density outranks molecular weight here.

04 — Applications and dose ranges

Where cationic PAM earns its cost.

Doses are product per unit of feed, already adjusted upward from textbook figures to what plants actually consume. Sludge figures are kg per tonne of dry solids; water figures are mg/L.

Municipal sludge dewatering

Belt press, screw press, centrifuge and plate-frame on activated, mixed or digested sludge. Raises cake solids and lifts the capture rate.

1.5–5 kg/t DS · grades C30 / C50

DAF and industrial sludge

Metal hydroxide, oily and food-processing sludge. Often preceded by PAC, which cuts polymer consumption.

2–10 ppm · grades C30 / C50

Paper retention & white water

Fines and filler retention, plus white-water clarification. Usually dosed after a cationic starch or PAC step.

0.2–1.0 kg/t paper · grade C10 / C30

Textile & dyeing effluent

Colour body removal and sludge conditioning in printing and dyeing plants, where anionic chemistry leaves colour in the water.

5–25 ppm · grade C80

Sugar & food clarification

Cane and beet juice clarification, starch and dairy process water. High-charge grade flocculates protein and colloid quickly.

0.5–5 ppm · grade C80

Oily wastewater

Refinery and metal-finishing effluent after DAF. Cationic charge breaks the oil-in-water emulsion together with PAC.

3–15 ppm · grades C30 / C50

Not on the list? Cationic PAM also runs in mining concentrate and tailings where the solids are cationic, in fermentation broth, and in construction slurry. Send the sludge source, dry solids content and the dewatering device — those three decide the grade more than anything else.

05 — Preparation and dosing

Charge density is wasted
if the solution is wrong.

Cationic polymer is dosed at lower concentration than anionic and is far less forgiving of over-mixing. The make-down skid is where most dewatering problems start.

Make-down procedure

01Dilute to 0.1–0.5% w/w. For sludge, make down at 0.2–0.5% and post-dilute to 0.05–0.1% at the injection point.
02Disperse at 400–600 rpm. Cationic powder wets out faster than anionic and forms lumps just as easily if it is dumped in.
03Hydrate at ~60 rpm for 30–50 min. Longer mixing does not improve a cationic solution; it only degrades it.
04Use within 24 hours. Cationic solutions lose activity faster than anionic in warm weather.
05Inject into the sludge line, not the tank. 5–15 seconds of contact before the dewatering device is usually right; static mixers are better than a centrifugal pump.

Five things that quietly ruin performance

Overdosing. Beyond the optimum the charge reverses and the sludge re-stabilises — cake solids drop and the filtrate gets turbid. If adding polymer makes it worse, you are past the peak.

Oxidants in the sludge. Residual chlorine, hypochlorite or peroxide destroys the polymer chain. Check whether the plant is chlorinating before the dewatering stage.

Mixing anionic and cationic. The two form an insoluble complex. Never share a make-down tank, a line or a dosing point.

Excessive shear. Centrifuge feed pumps and long pipe runs shear a cationic floc. Keep the run from injection to machine as short as the layout allows.

Damp storage. Cationic powder is hygroscopic. Bags that take on moisture cake into lumps that never dissolve — keep them sealed, on pallets, below 35 °C.

06 — Packaging and logistics

Loaded to the port you name.

25 kg woven bag

PE-lined PP woven bag with inner liner, 40 bags per pallet or 40 loose bags per bundle.

20–25 t per 20' FCL

750 kg jumbo bag

Four-loop FIBC with discharge spout, for plants with bulk hoppers and no manual handling.

18–20 t per 20' FCL

Terms and documents

FOB Shanghai / Qingdao, CIF, or DDP where we have a forwarder. COA, SDS, packing list and certificate of origin included.

Non-hazardous cargo · no DG declaration
07 — Compliance

What we hold, and
what we do not.

Cationic PAM is not a drinking-water chemical, and we say so before anyone writes it into a specification.

✓

GB/T 31246

Produced and tested to the Chinese national standard for cationic polyacrylamide, monomer ≤ 0.10%.

✓

ISO 9001 / 14001

Quality and environmental management certified across the production sites.

✓

SGS / CCIC

Third-party inspection available per shipment, at buyer's request and cost.

✕

Not for drinking water

Cationic PAM is not offered for potable-water treatment. For drinking water use PAC 29%, which is produced under a hygiene licence.

On the monomer limit. Cationic grade is supplied at ≤ 0.10% residual acrylamide by GB/T 31246. A lower-monomer run is possible on request, but it is a separate production batch with its own lead time — not an add-on after the order is placed.

08 — Questions buyers actually ask

Before you specify a charge density.

How do I choose between 10, 30, 50 and 80 mol%?

By the charge of the sludge, not its solids content. Raw activated sludge usually takes 20–40 mol%; anaerobically digested sludge takes 40–60 mol% because it carries more anionic colloidal material; high-charge duties such as dyeing effluent take 70–80 mol%. A jar test with a CST or SRF measurement settles it in an afternoon, and we supply the samples free.

Why does my cake get wetter when I add more polymer?

Because you have passed the charge optimum and re-stabilised the sludge. Cationic dosage has a peak, and beyond it the floc gets smaller and the filtrate more turbid. Cut the dose by 20% and run a ladder test — nine out of ten “polymer stopped working” cases are overdosing or a change in sludge age.

Do I need PAC as well?

Not always. Biological sludge usually needs cationic PAM alone. DAF float, oily wastewater and mixed chemical sludge often improve with PAC first, which reduces polymer consumption enough to pay for itself.

What dose per tonne of dry solids should I budget?

Budget 2–4 kg/t DS for a belt press on mixed sludge, 3–6 kg/t DS for digested sludge on a centrifuge, and 1.5–3 kg/t DS for a screw press. A plant with good conditioning and a modern machine often lands at the low end; an overloaded old press does not.

Can cationic PAM be used for drinking water?

No. We do not offer cationic PAM for potable water. Use PAC 29% (GB 15892) for coagulation and an anionic drinking-water grade for flocculation if a polymer is required at all.

How is it packed and shipped?

25 kg PE-lined woven bags on 40-bag pallets, or 750 kg jumbo bags. 20–25 t per 20' container. Non-hazardous cargo, no DG declaration. COA, SDS and packing list travel with the shipment; certificate of origin on request.

Next step

Tell us the sludge.
We will tell you the grade.

Sludge source, dry solids, the dewatering device and the cake solids you need. If you can send a 2-litre sample, we run the ladder test in our lab and return the dose curve with the quotation.

Reply within 12 working hours · data used for quotation only

Talk to us