Oil and gas: polymer where it earns,
coagulant where it protects.
Two different jobs share one supply chain. In the reservoir the polymer is a viscosity modifier and every point of molecular weight is money; at surface it is a waste-treatment chemical and every ppm of oil in water is a permit risk. We supply both, and we do not confuse them.
What goes into this water
Salinity and shear
are the whole story.
Produced water and injection water are hostile to polymers: high TDS, high temperature, iron, sulfide and mechanical shear. These are the figures that decide whether a standard grade survives or a special one is needed.
| Parameter | Typical range | Why it matters |
|---|---|---|
| Total dissolved solids | 2,000–120,000 mg/L | High salinity screens the polymer coil; above about 30,000 mg/L standard grades lose viscosity |
| Temperature | 30–90 °C | Above 70 °C hydrolysis accelerates in situ, which changes both viscosity and adsorption |
| Oil in water | 50–1,000 ppm | Sets the coagulant dose and whether a DAF or a hydrocyclone is the right first step |
| Hardness (Ca + Mg) | 200–5,000 mg/L | Very hard water needs a higher-charge polymer or a chelant; it also scales injection lines |
| Sulfide / iron | 0–50 mg/L | Both consume polymer and accelerate degradation — a quiet cause of dose creep |
| Shear at the wellhead | 10³–10⁵ s⁻¹ | Choke valves and ESPs cut molecular weight; viscosity loss of 30–60% is normal without protection |
Surface water, in order.
Produced water treatment is a sequence of removals: free oil first, then emulsified oil, then solids. Each step has a chemical that belongs to it and a step where adding chemical is wasted money.
The failure mode to avoid is polymer carry-over into the filters: an overdosed DAF blinds the media within days and the plant blames the filter. Watch turbidity at the DAF outlet, not just oil in water.
Four products, two duties.
EOR and surface treatment use different grades of the same chemistry — specify them separately.
Anionic PAM A1610 / A2010
High molecular weight for viscosity and profile control. Requires screened, deoxygenated brine and a low-shear make-down skid — a centrifugal pump will cost you a third of the viscosity.
1,000–2,500 mg/L →Produced waterPAC 28% industrial
Breaks oil-in-water emulsions and destabilises the solids that stabilise them. Cheaper per m³ than increasing the polymer dose.
30–150 g/m³ →SludgeCationic PAM C30 / C50
Flocculates DAF float and tank bottoms for centrifuge or press. Charge density chosen on the sludge, not on the water.
3–15 ppm →DrillingNon-ionic PAM N10
Viscosifier and fluid-loss control in water-based mud, including brine and seawater systems where anionic grades precipitate.
1–5 kg/m³ →On EOR specifically. We will not quote a polymer flood grade on a distilled-water viscosity curve. Send the synthetic brine, the reservoir temperature and the shear history, and we will discuss what the polymer will actually do downhole — including where it will not work.
Dose reference.
Surface doses are per cubic metre of water; sludge doses per tonne of dry solids; EOR per cubic metre of injected slug.
| Duty | Product | Dose | Target |
|---|---|---|---|
| Produced water clarification | PAC 28 + C30 | 60–200 g/m³ + 3–10 ppm | Oil in water < 10 ppm, turbidity < 20 NTU |
| DAF float dewatering | Cationic C50 | 2–6 kg/t DS | Cake 18–25% DS |
| Drilling mud | Non-ionic N10 | 1–5 kg/m³ | Funnel viscosity and fluid loss on spec |
| EOR polymer slug | Anionic A1610 / A2010 | 1,000–2,500 mg/L | Viscosity retention > 70% at the sand face |
| Flowback water | PAC 28 + C30 | 80–250 g/m³ + 5–15 ppm | TSS < 50 mg/L for disposal or reuse |
| Tank bottom sludge | Cationic C30 | 3–8 kg/t DS | Volume reduction 30–50% |
Where the money leaks.
Four issues specific to oilfield water, all of them expensive and all of them avoidable.
Shear at the choke
A high-MW polymer loses 30–60% of its viscosity across a choke or an ESP. Nothing in the formulation fixes that — the fix is mechanical, or it is accepting a lower target viscosity.
Oxygen and iron contamination
Dissolved oxygen plus ferrous iron generates radicals that cut the polymer chain. Deoxygenation and oxygen-scavenger control are part of polymer flood design, not an afterthought.
Salinity overshoot
A grade that gives 40 mPa·s in 5,000 mg/L brine can drop below 10 mPa·s at 80,000 mg/L. Always quote viscosity at reservoir salinity, not at the salinity that is convenient to test.
Polymer carry-over to filters
Overdosing the DAF sends unadsorbed polymer to the media filters, where it blinds them and raises differential pressure. Cut the dose and check turbidity at the DAF outlet.
Before you specify an oilfield grade.
Do you supply polymer for polymer flooding?
Yes — high-MW anionic PAM in the A1610/A2010 range, with the brine screening and low-shear make-down that a flood needs. Send the synthetic brine analysis and reservoir temperature; we will tell you what viscosity to expect honestly, including if a standard grade is the wrong choice.
What salinity can your polymers handle?
Standard anionic grades perform well to roughly 30,000 mg/L TDS. Above that, viscosity loss becomes significant unless the grade is matched to the brine. We stock a high-salinity variant and will test your water rather than guess.
Can you treat flowback and produced water for reuse?
Yes: PAC to break the emulsion, cationic PAM to flocculate, then filtration. The design question is the target — reuse for fracturing is a different specification from reinjection for pressure support, and the chemical dose differs accordingly.
What about H₂S and iron?
Both consume polymer and both accelerate degradation. If your water carries sulfide or ferrous iron above about 5 mg/L, budget a higher dose and consider scavenging upstream — otherwise the dose creeps upward and nobody knows why.
Is the product hazardous for transport?
No. Polyacrylamide and PAC are non-hazardous cargo with no DG declaration. SDS, COA and packing list travel with every shipment.
Send the brine.
Get a grade that survives it.
Brine analysis, temperature, shear at the injection point and the target viscosity or water quality. We reply with a grade, a dose range and the test we would run before committing.
