Home/Applications/Oil & gas
EOR · produced water · drilling fluids

Oil and gas: polymer where it earns,
coagulant where it protects.

Two different jobs share one supply chain. In the reservoir the polymer is a viscosity modifier and every point of molecular weight is money; at surface it is a waste-treatment chemical and every ppm of oil in water is a permit risk. We supply both, and we do not confuse them.

2,000–120,000mg/L TDS
<10 ppmOIL IN WATER
1,000–2,500mg/L EOR slug
70%+VISCOSITY RETENTION
What goes into this water
Anionic PAM A1610 / A2010EOR viscosity and profile control — high MW, screened brine, low-shear make-down.1,000–2,500 mg/L slug
PAC 28% industrialBreaks produced-water emulsions together with the cationic polymer.30–150 g/m³
Cationic PAM C30 / C50Flocculates oily sludge and DAF float before the centrifuge.3–15 ppm
Non-ionic PAM N10Drilling mud viscosifier and fluid-loss control in brine systems.1–5 kg/m³ mud
01 — Water profile

Salinity and shear
are the whole story.

Produced water and injection water are hostile to polymers: high TDS, high temperature, iron, sulfide and mechanical shear. These are the figures that decide whether a standard grade survives or a special one is needed.

ParameterTypical rangeWhy it matters
Total dissolved solids2,000–120,000 mg/LHigh salinity screens the polymer coil; above about 30,000 mg/L standard grades lose viscosity
Temperature30–90 °CAbove 70 °C hydrolysis accelerates in situ, which changes both viscosity and adsorption
Oil in water50–1,000 ppmSets the coagulant dose and whether a DAF or a hydrocyclone is the right first step
Hardness (Ca + Mg)200–5,000 mg/LVery hard water needs a higher-charge polymer or a chelant; it also scales injection lines
Sulfide / iron0–50 mg/LBoth consume polymer and accelerate degradation — a quiet cause of dose creep
Shear at the wellhead10³–10⁵ s⁻¹Choke valves and ESPs cut molecular weight; viscosity loss of 30–60% is normal without protection
For EOR projects we ask for the brine analysis and the injection temperature before quoting a grade. A polymer that performs on distilled water in a lab is not evidence for a 90 °C, 80,000 mg/L reservoir.
02 — Treatment train

Surface water, in order.

Produced water treatment is a sequence of removals: free oil first, then emulsified oil, then solids. Each step has a chemical that belongs to it and a step where adding chemical is wasted money.

SEPARATIONFree oil removalThree-phase separator or CPI. No chemical needed here.—
BREAKINGEmulsion breakingPAC or a reverse demulsifier into the produced-water line.30–150 g/m³
FLOTATIONDAF / IGFCationic PAM flocculates the oil-solid agglomerate for removal.3–15 ppm
POLISHINGFiltrationMedia or walnut shell filters; polymer carry-over blinds them.<10 ppm OIW
DISPOSALSludgeCationic PAM on the float for centrifuge or filter press.2–6 kg/t DS
REINJECTIONInjectionWater quality to protect the formation and the injectors.—

The failure mode to avoid is polymer carry-over into the filters: an overdosed DAF blinds the media within days and the plant blames the filter. Watch turbidity at the DAF outlet, not just oil in water.

04 — Dose reference

Dose reference.

Surface doses are per cubic metre of water; sludge doses per tonne of dry solids; EOR per cubic metre of injected slug.

DutyProductDoseTarget
Produced water clarificationPAC 28 + C3060–200 g/m³ + 3–10 ppmOil in water < 10 ppm, turbidity < 20 NTU
DAF float dewateringCationic C502–6 kg/t DSCake 18–25% DS
Drilling mudNon-ionic N101–5 kg/m³Funnel viscosity and fluid loss on spec
EOR polymer slugAnionic A1610 / A20101,000–2,500 mg/LViscosity retention > 70% at the sand face
Flowback waterPAC 28 + C3080–250 g/m³ + 5–15 ppmTSS < 50 mg/L for disposal or reuse
Tank bottom sludgeCationic C303–8 kg/t DSVolume reduction 30–50%
These are surface-treatment ranges. EOR design is a reservoir-engineering exercise, not a catalogue selection — treat the figure above as the order of magnitude, then run core flood or at least a rheology sweep on the actual brine.
05 — What goes wrong

Where the money leaks.

Four issues specific to oilfield water, all of them expensive and all of them avoidable.

Shear at the choke

A high-MW polymer loses 30–60% of its viscosity across a choke or an ESP. Nothing in the formulation fixes that — the fix is mechanical, or it is accepting a lower target viscosity.

Oxygen and iron contamination

Dissolved oxygen plus ferrous iron generates radicals that cut the polymer chain. Deoxygenation and oxygen-scavenger control are part of polymer flood design, not an afterthought.

Salinity overshoot

A grade that gives 40 mPa·s in 5,000 mg/L brine can drop below 10 mPa·s at 80,000 mg/L. Always quote viscosity at reservoir salinity, not at the salinity that is convenient to test.

Polymer carry-over to filters

Overdosing the DAF sends unadsorbed polymer to the media filters, where it blinds them and raises differential pressure. Cut the dose and check turbidity at the DAF outlet.

On produced water reuse. Water that meets the injection specification is worth more than water that meets the discharge limit. Design the chemical program to the injection spec and the discharge permit usually takes care of itself.
<10 ppmOil in water for reinjection
70%+EOR viscosity retention
<20 NTUDAF outlet turbidity
30–50%Sludge volume reduction
06 — Questions from plant engineers

Before you specify an oilfield grade.

Do you supply polymer for polymer flooding?

Yes — high-MW anionic PAM in the A1610/A2010 range, with the brine screening and low-shear make-down that a flood needs. Send the synthetic brine analysis and reservoir temperature; we will tell you what viscosity to expect honestly, including if a standard grade is the wrong choice.

What salinity can your polymers handle?

Standard anionic grades perform well to roughly 30,000 mg/L TDS. Above that, viscosity loss becomes significant unless the grade is matched to the brine. We stock a high-salinity variant and will test your water rather than guess.

Can you treat flowback and produced water for reuse?

Yes: PAC to break the emulsion, cationic PAM to flocculate, then filtration. The design question is the target — reuse for fracturing is a different specification from reinjection for pressure support, and the chemical dose differs accordingly.

What about H₂S and iron?

Both consume polymer and both accelerate degradation. If your water carries sulfide or ferrous iron above about 5 mg/L, budget a higher dose and consider scavenging upstream — otherwise the dose creeps upward and nobody knows why.

Is the product hazardous for transport?

No. Polyacrylamide and PAC are non-hazardous cargo with no DG declaration. SDS, COA and packing list travel with every shipment.

Next step

Send the brine.
Get a grade that survives it.

Brine analysis, temperature, shear at the injection point and the target viscosity or water quality. We reply with a grade, a dose range and the test we would run before committing.

Reply within 12 working hours · data used for quotation only

Talk to us